MEDICAL
LASERS
   Laboratory for laser medicine was formed in POLYUS Research & Development Institutein 1965. The carried-out investigations allowed to develop the first serial laser medical systems for surgery, ophthalmology and oncology. These systems based on CO2 and ND:YAG lasers. Lately, semiconductor lasers started to use in therapeutic applications. Today our laser medical systems are widely used by leading medical centers and hospital.
   At present POLYUS Research & Development Institute is focused on following main applications:
-cardiology and physiotherapy;
-surgery and oncology;
-ophthalmology;
-cosmetology and dermatology;
-veterinary;
-ecology.




MODULE-GF
Laser Medical Device For Treatment Of Oncologic Diseases




Module-GF
     The MODULE-GF device is designed for combined photodynamic therapy and laser-induced thermotherapy of oncologic diseases. The therapeutic effect is provided by laser radiation at 670 um in the photodynamic therapy channel and at 810…1060 um in the laser-induced thermotherapy channel. The delivery of optical radiation of the photodynamic therapy channel and the thermotherapy channel is carried out simultaneously via a single optical fiber. The device allows both simultaneous and individual use of the modes of photodynamic therapy and thermotherapy to treat oncologic diseases.
     To monitor the therapy procedure, the device is equipped with a contactless pyrometric temperature sensor with a laser pointer, a contact invasive temperature sensor, a power meter, a power density meter, a temperature control (calibration) unit. Definition of a therapy mode cyclogram may be done from the control keyboard. The parameters of operating modes are shown on the display. The device can be used in general surgery, endo- and laparosurgery, dermatology, stomatology and therapy, as a blood coagulator and a scalpel.

Specifications
In the photodynamic therapy channel laser emission at 670 nm with an output power of 0.01 ... 1 W; a step of 0.01 W.
In the thermotherapy channel laser emission at 810 ... 1060 nm with output power of 0.1 ... 10 W; step of 0.1 W. A concrete value of output optical power from this range is coordinated with a customer.
Energy delivery: single optical fiber of 3 m length, Ø600 µm
The tissue heating temperature feedback loop provides automatic maintenance of a specified temperature to an accuracy of ±0.2°C within a temperature range of 30 ... 50°C.
The built-in microprocessor provides program realization of a therapy mode.



EPILASER
Laser Assisted Hair Removal

Epilaser    Laser Hair Removal is rapidly becoming one of the most sought after cosmetic procedures today. The EPILASER offers the greatest advantage in hair removal, both to the physician and the patient, when important treatment elements such as safety, effectiveness, speed, treatment comfort, recovery time and cost are all considered.
   The EPILASER is used to treat all skin types with virtually no side effects. The laser's burst of energy is strong enough to damage the hair structure but too shot to heat the surrounding skin. This long-pulsed laser light, having a 1064 nm wavelength, is minimally absorbed in superficial skin layers, and pronounced scattering up to 5 mm occurs targeting in deeper follicles. No patient had hypopigmentation or hyperpigmentation.
   The EPILASER promotes significant growth delay, which, depending on the hair type and location, will last from an average of 30 - 90 days or longer, with each treatment.
   The EPILASER supports large spot size and fast (up to 3 Hz) repetition rates.
   Because there is no heat transmitted to surrounding skin areas, patients feel nothing more than a tingling sensation as the laser light pulses against their skin.

Nd:YAG LASER PERFORMANCE
Wavelength1064 nm
Energy10 J
Pulse width5 ms
Pulse repetition rateup to 3 Hz
Spot size3-5-7 mm
Coolingclosed cycle water-to-air
Input power220/240V, 1 kW Single phase
Weight 50 kg
Size (LxWxH)25x63x75 cm
Optical deliveryOptical Fiber, 2 m
Microprocessor controlled



DERMALAG
Laser System For Cosmetic Application

Epilaser    DERMALAG is a Q-switched, frequency doubled Nd:YAG laser. DERMALAG supports all the basic cosmetic applications including tattoo removal, pigmented lesion removal and vascular lesion treatment. The 1064 nm (infrared) wavelength of DERMALAG is used in the removal of dark-ink tattoo. Since there is comparatively low absorption by melanin at the longer wavelength, a significantly lower risk of hypopigmentation exists at 1064 nm in comparison to other lasers in the 600-800-nm range. Additionally, the short pulse width (20 ns) reduces the risk of scarring by limiting the tissue exposure to heat build-up.
   The 1064 nm (infrared) wavelength with energy fluences of 4-12 J/cm2 is extremely successful in the treatment of dermal melanocytosis such as nevus of Ota and aberrant Mongolian spots.
   The 532 nm (green) wavelength is ideally suited for the removal of red tattoo ink. Significant red ink removal may be achieved with one treatment at 532 nm at fluences of 5 J/cm2.
   The 532 nm (green) wavelength with fluences of 2-5 J/cm2 has a significant application in the removal of vascular lesions and epidermal pigmented lesions.

Nd:YAG LASER PERFORMANCE
Wavelength1064, 532 nm
Pulse energy at
  1064 nm
  532 nm

0.8 J
0.4 J
Pulse energy density at
  1064 nm
  532 nm

8 J/cm2 @ 4.0 mm
5 J/cm2 @ 3 mm
Pulse width8 ns
Pulse repetition rate10 Hz
Spot size at
  1064 nm
  532 nm

3-5-7 mm
2-3-5 mm
Coolingclosed cycle water-to-air
Input power220/240V, 1 kW Single phase
Weight 50 kg
Optical deliveryArticulated arm
Microprocessor controlled



YATAGAN-4-MICRO
Laser Set for Ophthalmology

Yatagan    The YATAGAN-4-MICRO Laser Set for Ophthalmology is a laser photodestructor designed to carry out microsurgical operations on the anterior chamber of the eye and the lens capsule by a focused beam of a Q-switched pulsed neodymium laser.

YATAGAN-4-MICRO's potentialities:

Laser Specifications
Wavelength1079 nm
Pulse energy0.5...10 mJ
Angle of convergence15°, 20°
Min. diameter of focal spot20 µm
Pulse duration5...8 ns
Mode of operation single pulses or dual-pulse burst
Weight (without slit lamp)3 kg



ANTIBOL
Device for Domestic Treatment

Antibol


ANTIBOL is used:
  • for electric pulse treatment of various locomotorium disease (osteochondrosis, arthritis, radiculitis, neuralgia, etc.);
  • for red beam treatment of inflammatory process (acute respiratory disease, angina, paradontosis, furuncles, toothache, etc.);
  • treatment of herpes and healing wounds of different origin (burns, cuts, chaps, etc.).
Contraindication:
  • oncologic diseases;
  • active tuberculosis;
  • acute myocardial infarction;
  • presence of artificial cardiac stimulator;
  • pregnancy.

The ANTIBOL (antipain) device is an impulse anaesthetic stimulator of red light supplied with electric massage plates for reflex therapy.

Features
The device provides a possibility to produce an effect both electric energy when using electrodes on the device housing, and with light energy when using a light pencil that is connected to the housing by a flexible wire. The therapeutic effect is based on the well-known phenomenon of increase of metabolic rate in tissues and cells under electric pulses, and as a consequence analgetic, anti - inflammatory, antiedemic and general restorative effects are achieved in the organism. Low-energy red light radiation has an analogous effect on the mucous membrane. The human skin is practically transparent to the radiation used in this device, so a positive effect can be achieved almost in 100% of cases when light pulse stimulation is used. The main distinction of the ANTIBOL device from all analogous devices is automatic continuous tuning of repetition rate of electric and light pulses (40...250 Hz for 2 min), which on the one hand, does not allow the human organism to be habituated to an external irritant (which enhanced considerably the effect of exposure). On the other hand, the wide pulse repetition rate tuning range assures good agreement with individual frequencies of biorhythms of the human organism, which also increases resonantly the efficiency of exposure. In the mode of electrostimulation the efficiency is not less than 85%.



ALTP-4 and ALTP-4-1
Laser Therapeutic Devices

ALTP    ALTP-4 and ALTP-4-1 Laser Therapeutic Devices are based on array semiconductor emitters. The devices are designed for noninvasive supravenous blood irradiation.
   Both devices designed for different applications depending on a wavelength and laser power.

Array emitter is efficient in: Specifications
DeviceOutput wavelengthOutput powerApplications
ALTP-41260 nm0.2 mWNoninvasive supravenous blood irradiation in cardiology, rheumatology, pulmonology
ALTP-4-1970 nm120 mWLaser acupuncture, irradiation of joints and vessels in rheumatology and eranoipuncture.
Laser therapy in surgery, stomatology, dermatology.
External and intracavitary irradiation using the optical handpieces.

Service Potentialities:



YARILO-SYNCHRO
Electrical & Laser Therapeutic Device for Urology

Yarilo The device is designed to treat a wide range of therapeutic diseases. Treatment is provided by complex action of laser radiation and electrical current in four channels:
  • infrared pulse radiation;
  • infrared continuous wave radiation;
  • red continuous wave radiation;
  • electrostimulation
The increase in efficiency is provided by synchronization of laser power and electrostimulation current with patient's pulse.

The device allows:
  • delivery of electrostimulation pulses, red and IR laser radiation directly to the prostate via the catheter electrode;
  • continuous adjustment of electrostimulation frequency, which makes it possible to act selectively on all muscles of the prostate;
  • synchronization of pulses of all channels of action within 0.5 ... 50 Hz range;
  • modulation of intensity of all channels of action by signals from the pulse rate meter;
  • biosynchronization of electrostimulation and photoactivation of the smooth musculature with rhythms of local blood flow that provides significant increase in treatment efficiency;
  • carrying out electropuncture and laserpuncture in biologically active points.
Specifications
Parameters of electrostimulation channel: 
Output voltage range0.3 - 30 V
Rate of bipolar pulses400 µs
Duration of positive and negative pulses100 µs
Time between positive and negative pulses100 µs
Duration of bipolar pulse train8 ms
Repetition rate of bipolar pulse trains0.5 - 50 Hz
Parameters of red CW radiation: 
Laser wavelength670 nm
Range of average laser output0.2 - 15 mW
Parameters of IR pulse radiation 
Laser wavelength890 nm
Average laser output0.6 mW
Repetition rate of pulse trains0.5 - 50 Hz
Modulation frequency of pulse train2.5±0.25 Hz
Parameters of IR CW radiation: 
Laser wavelength810 nm
Range of average laser output4 - 350 mW
Frequency modulation of laser output0.5 - 50 Hz
Timer setting1/60...60 min
Smooth regulation of frequency modulation of the channels0.5-50 Hz
Continuous operation8 hours
Size420x275x115 mm
Weight10 kg
Power supply220V, 50 Hz
Power consumption60 W




ATO-1-150
Therapeutic Device For Oncology

ATO-1-150 The ATO-1-150 Therapeutic Device for Oncology is designed for treatment of oncologic diseases by the photodynamic therapy using hematoporphyrin preparations and the photosense preparation.

Advantages:
  • the possibility to change power density and emission band;
  • measurement of power density by the meter from delivery set;
  • easy and convenient to use;
  • low cost and high medical efficiency.
Specifications
Output spectral range630 nm ±20 nm (photogem)
675 nm ± 20 nm (photosense)
Power density on biological tissueup to 200 mW/cm2
Spot size at power density of 200 mW/cm2up to 1 cm2
Light deliveryfiberoptic cable
Mode of operationcontinuous
Power supply220 V, 50 Hz, 200 W




VEGA-MV
Portable Laser Veterinary Apparatus

Vega-MV The laser veterinary apparatus is designed for medical treatment of domestic animals for bone-articulation pathology, festering wounds, mastitis, scalds, endometritis, bronchopneumonia, etc. The laser application provides highly effective painless treatment without any drugs. It has a pronounced analgetic effect and presents a possibility of obtaining ecologically pure animal protection.
Laser therapy increases the immunity and improves the general state of organism, adaptive, correcting and compensating functions of the organs, tissues and the organism as a whole.
The VEGA-MV is a small portable apparatus with an autonomous power supply, which permits its broad application under conditions both of veterinary hospitals and of private practice. The therapeutic efficiency for clinical mastitis achieves 85%, for subclinical mastitis 98.5 - 100%, and for endometritis 86.5%. The Department of Veterinary of the Ministry of Agriculture and Food of RF approves the VEGA-MV laser apparatus for application in veterinary practice.

Specifications
Average output power10 - 15 mW
Exposure time1; 2; or 5 min
Continuous operation time8 hours
Time of full charge of accumulator battery12 - 14 hours
Lifetime at 8-hours operation a day2 years
Dimensions:
- length
-diameter

283 mm
68 mm
Weight0.4 kg