POLYUS R&DI
Products About News Form

SOLID-STATE

LASERS
POLYUS Research & Development Institute carries out a wide range of research and developments in the field of solid-state lasers for following main applications:
- industrial laser systems;
- medical laser systems;
- laser rangefinders;
- scientific research.
Our lasers are based on Nd:YAG and Nd:YAP crystals. The recent developments also use Cr, Nd:GSGG; Cr, Tm, Ho:YAG; Er:YAG; Ti:Saphire and Cr4+:YAG crystals. Output of CW Nd:YAG and Nd:YAP lasers achieves 1 kW in CW and pulse energy up to 3J in pulse operation IR range. Harmonic generators and OPO-converters are used to expand emitting range to UV and IR range.




LT-Series Nd:YAG Lasers for Optical Location

  • High Repetition Rate

  • Frequency Conversion

  • Self contained Q-switch Driver

  • High Efficiency and Reliability

  • Vibration and Shock Resistance

  • Wide Temperature Range

  • LT-4Z Development of pulsed solid-state lasers with frequency conversion is one of prior activities of POLYUS Research
    & Development Institute.Having experience of many years our specialists continue to improve their technical performance and reliability.LT-Series Nd:YAG LT-5
    LT-6 Lasers meet to highest requirements for wide range of customers exploitating laser systems for optical location.

    SPECIFICATIONS
    ParameterModel
    LT-4ZLT-4Z1LT-5X LT-5ZLT-8ESLT-9
    Wavelength, nm532532 10645321064532 10641570532
    Pulse energy, mJ2030...50 20080300...400150..200 5020up to 50
    Pulse repetition rate, Hz100...500 100...50020050...100 20…3020...100
    Pulse width, ns15...2015...20 10...1210...12 10...1510...15
    Beam divergence, mrad5 5<45 5 3
    Beam diameter, mm 55 5 8 55
    Power consumption, kW2.5 2.85.04.0 0.34.0
    Weight, kg9  77 <1<2.5
    Dimensions, mm500x150x70  450x8.60x90 460x130x90190x45x70 220x110x60

    Special Features
    LT-4Z Q-switched intracavity doubled Nd:YAG laser
    LT-4Z1 high repetition rate intracavity frequency-doubled Nd:YAG laser
    LT-5X Q-switched Nd:YAG oscillator-amplifier with extracavity harmonic generation
    LT-5Z high repetition rate frequency-doubled Nd:YAG laser
    LT-8ES compact Nd:YAG:OPO eye-safe laser
    LT-9 compact pulsed intracavity frequency-doubled Nd:YAG laser
    LT-8ES
    LT-Series Nd:YAG Lasers meet your needs for reliability in harshest environments applications:
    • mobile lidar systems for atmosphere remote sensing and ecological monitoring;
    • high-repetition rate eye-safe rangefinders;
    • airborne systems for hydrographic research of coastal side
    LT-9


    Water-Air-Cooled Compact Pulsed Lasers
    SPECIFICATIONS
    ModelLTI-137LTI-138 LTI-240LTI-245LTI-246LTI-244LTI-444
    Wavelength, nm10641079 103410641079540
    Pulse energy
    TEMmn, J
    TEM00, J
    0.40.20.10.2

    0.1
    0.41.50.2
    Pulse repetition rate, Hz502010
    Pulse duration, ns1051012
    Beam diameter, mm53.88108
    Beam divergence, mrad51.57
    Pulse-to-pulse stability, %2323
    Power supply220 V, 50 Hz
    Laser head dimensions, mm380x75x75500x160x160380x75x75
    Power supply and cooling
    unit dimensions, mm
    500x240x500500x480x500500x240x500




    3 Vvedensky St., Moscow, 117342, Russia
    tel:+7 095 3330389 fax:+7 095 3330256
    e-mail: mail@polyus.msk.ru

    http://www.polyus.msk.ru